Model

P-2000 Digital Polarimeter

P-2000 with Na source

For users requiring purity and identification measurements of pharmaceuticals and sugars using the 589 nm D-line of the sodium lamp.

P-2000 with Hg source

The P-2000 Hg system couples a mercury lamp and 6 interference filters that span the visible to UV region for more analytically demanding laboratories.
Available interference filters: 578, 546, 436, 405, 365, 334, 313, 302, 296, 280, 253 nm

P-2000 with Na and Hg sources

The P-2000 Hg-Na system couples a mercury and sodium lamp and 7 interference filters that span the visible to UV region for more analytically demanding laboratories. Available interference filters: 589, 578, 546, 436, 405, 365, 334, 313, 302, 296, 280, 253 nm

P-2000 with WI source

The P-2000 WI system includes a tungsten halogen lamp and 589 nm inference filter for routine pharmaceutical measurements with the flexibility to add additional filters as applications and needs grow. Available interference filters: 880, 633, 589, 578, 546, 436, 405, 365, 334, 325 nm

P 2000 B
ALCOA

ALCOA+ Data Integrity Spectra Manager 2.5 CFR

Regulatory compliance for 21 CFR part 11 is available as an option with PC based Spectra Manager CFR™. JASCO Spectra Manager 2.5 CFR is designed and developed under ALCOA+ and is a total solution platform to create accurate and complete data.

User Management

Based on the dual security structure ([Access Level] and [Work Group]), it is possible to manage different authorization process in flexible and independent as total analysis systems, instrumentations and analytical applications.

Enduring Electronic Record

Based on prohibiting function to delete electronic record and to overwrite save, and also functions for automatic backup and restore data, electronic records can be saved properly and can be searched accurately during the data lifecycle.

Audit Trail

It is categorized as 3 different records (system log, application log and data log), and it is recorded.
Each log can be filtered and displayed under recorded date, user name etc, and it can be exported to audit trail review as text file.

Computerized System Validation

Spectra Manager 2.5 CFR is developed and manufactured properly under quality control system adapted ISO 9001, and adapted CSV standard.

User Account Security

Based on functions to prevent duplicate account or to protect password, and to prevent unauthorized access, administrative authorizations as system access and electric signature etc., can be managed strictly.